Search results for "impression materials"

showing 7 items of 7 documents

Accuracy of check-bite registration and centric condylar position

2002

In a dentate subject a jaw relation can either be determined in maximum intercuspation and is as such given by the occlusal morphology, or the mandibular position can be allocated according to the centric position of the condyles. For comprehensive restorative treatment or analytic measures of the occlusion it is important to record the centric condylar position. Various registration methods have been described in the literature, but there is no consensus on which is the 'best'. The aim of the present study was therefore to assess the accuracy of various registration methods and evaluate a possible influence of the used materials. Four dentists were involved in the clinical part of the stud…

AdultMaleDental ArticulatorsAdolescentSurface PropertiesComputer scienceArticulatorStatistics as TopicAcrylic ResinsDentistryMandibleStatistics NonparametricCondylestomatognathic systemEugenolOcclusionHumansRestorative dentistryGeneral DentistryOcclusal AdjustmentOrthodonticsbusiness.industryDental Impression MaterialsMandibular CondyleReproducibility of ResultsSignal Processing Computer-AssistedCentric RelationEquipment DesignCentric relationMiddle AgedModels DentalMaximum intercuspationJaw Relation RecordTinWaxesBite registrationFemaleZinc OxidebusinessJournal of Oral Rehabilitation
researchProduct

Functional impression and jaw registration: a single session procedure for the construction of complete dentures*

2004

The conventional fabrication of complete dentures involves two separate clinical sessions for functional impression making and jaw registration. The presented method combines both procedures in one session. The aim of this study was to survey the three-dimensional tooth positions in complete dentures with reference to the ridges to establish arbitrary guideline values that could be used for the manufacturing of tooth-position analogue plastic rims on functional impression trays. New complete dentures were fabricated by supervised undergraduate students in the conventional manner for 104 edentulous patients. The position of the maxillary teeth was surveyed in the horizontal plane using the S…

AdultMaleDental InstrumentsDental Impression TechniqueComputer sciencemedicine.medical_treatmentDentistryMandibleDental Occlusion Balancedstomatognathic systemMaxillamedicineHumansDental Impression TechniqueMaxillary central incisorDenture DesignGeneral DentistryAgedAged 80 and overVertical dimension of occlusionDenture Completebusiness.industryDental occlusionDental Impression MaterialsVertical DimensionMiddle Agedstomatognathic diseasesDenture DesignMaximum intercuspationJaw Relation RecordDental impression materialFemaleMouth EdentulousDenturesbusinessJournal of Oral Rehabilitation
researchProduct

Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material ver…

2019

Background The aim of this study was to compare a conventional technique (elastomeric impression material - EIM) and a digital technique (scanner digital model – SDM) on a six-analog master model (MM) to determine which was the most exact. Material and Methods Twenty impressions were taken of a master model (EIM) and twenty scanned impressions (SDM) (True Definition). A coordinate measuring machine (CMM) was used to measure the distances between adjacent analogues (1-2, 2-3, 3-4, 4-5, 5-6), intermittently positioned analogues (1-4, 3-6) and the most distal (1-6). Reference values were established from the master model, which were compared with the two impression techniques. The significance…

ScannerDental Impression TechniqueIn Vitro TechniquesCoordinate-measuring machine03 medical and health sciences0302 clinical medicineIn vitro study030212 general & internal medicineGeneral DentistryMathematicsConventional techniqueDental ImplantsIntraoral scannerResearchDental Impression Materials030206 dentistryDirect Technique:CIENCIAS MÉDICAS [UNESCO]Models DentalImpressionOtorhinolaryngologyElastomersDimensional Measurement AccuracyReference valuesUNESCO::CIENCIAS MÉDICASComputer-Aided DesignSurgeryOral SurgeryBiomedical engineeringMedicina oral, patologia oral y cirugia bucal
researchProduct

Resistance to disinfection of a polymicrobial association contaminating the surface of elastomeric dental impressions.

2009

The aim of this study was to evaluate the ability to resist disinfection of a polymicrobial association contaminating the surface of dental impressions obtained with two different elastomers: a polyether (Impregum) and an addition-polymerized silicone (Elite). Impressions were contaminated with a mixture of three biofilm-forming microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans) and disinfected immediately after contamination, or after microbial layers were allowed to develop during a six-hour storage. Two commercial disinfectants were tested: MD 520 containing 0.5% glutaraldehyde and Sterigum Powder without glutaraldehyde. Residual contamination was recover…

Settore MED/07 - Microbiologia E Microbiologia ClinicaStaphylococcus aureusPolyether Addition-polymerized silicone Glutaraldehyde Quaternary ammonium compounds DisinfectionDental Impression MaterialsColony Count MicrobialDental DisinfectantsDisinfectionQuaternary Ammonium CompoundsResins SyntheticSettore MED/28 - Malattie OdontostomatologicheGlutaralBiofilmsCandida albicansMaterials TestingPseudomonas aeruginosaSilicone ElastomersEquipment Contamination
researchProduct

Study of the interocclusal distortion in impressions taken with different types of closed-mouth trays and two types of impression materials

2010

The aim of this study was to compare different types of impression trays for the closed-mouth impression technique, using two different types of impression material. For this study, five different types of impression trays were used with two different types of impression materials, one of addition silicone and the other of polyether. We designed a model used for taking the impressions and for measuring interocclusal distortion. The results obtained show that the impression trays COE (GC (R) GC America INC. Alsip) and Premier (Premier (R), Premier Dental Products Co. Canada) show a lesser degree of interocclusal distortion when taking closed-mouth impressions. In terms of impression material…

medicine.medical_specialtyDental Impression TechniqueComputer scienceClosed-Mouth ImpressionsOdontologíaImpression traysDental OcclusionCirugíaDistortionDentistry Oral Surgery & MedicinemedicineDental Impression TechniqueDual-Arch ImpressionsGeneral DentistryOrthodonticsDental occlusionDental Impression MaterialsPolyetherEquipment Design:CIENCIAS MÉDICAS [UNESCO]Closed mouthSurgeryImpressionImpression TraysTrayOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASDental impression materialSurgeryInterocclusal DistortionMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Dimensional stability of contemporary irreversible hydrocolloids: humidor versus wet tissue storage.

2012

Statement of problem The storage time and conditions of irreversible hydrocolloid impressions affect their accuracy and in turn the precision of the definitive cast. Recommendations for proper storage are, however, based on theoretical assumptions rather than facts. Purpose The purpose of this study was to assess the influence of the 2 most common storage conditions on the dimensional stability of 7 contemporary irreversible hydrocolloids (IH) for a period of up to 7 days. Material and methods Twelve specimens per material (Blueprint, Cavex CA37, Cavex ColorChange, Jeltrate, Orthoprint, Cavex Orthotrace, and Tetrachrom) were fabricated according to ISO/CD 21563. The specimens were either st…

medicine.medical_specialtyMaterials scienceDental Impression TechniqueTime FactorsPost hocAlginatesDental Impression MaterialsReproducibility of ResultsHumidityModels DentalSurgerySpecimen HandlingmedicineTukey's range testHumansDental Impression TechniqueColloidsOral SurgeryBiomedical engineeringThe Journal of prosthetic dentistry
researchProduct

The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials

2008

The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with additionpolymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after th…

medicine.medical_specialtyTime FactorsMaterials scienceSurface PropertiesDisinfectantDentistryimpression materials disinfectants dimensional stability disinfection polyether addition-polymerized siliconeElastomerSilicone rubberchemistry.chemical_compoundSettore MED/28 - Malattie OdontostomatologicheImmersionMaterials TestingmedicineImmersion (virtual reality)HumansGeneral Dentistrybusiness.industryDental Impression MaterialsDental DisinfectantsAmmonium compoundsSurgeryImpressionDisinfectionQuaternary Ammonium CompoundsResins SyntheticElastomerschemistryGlutaralSilicone ElastomersDental impression materialGlutaraldehydebusiness
researchProduct